15
AZM201
Operating instructions
Solenoid interlock
EN
2.5 Technical data
Standards:
IEC 60947-5-3, ISO 14119,
ISO 13849-1, IEC 61508, IEC 62061
Enclosure:
glass-fibre reinforced thermoplastic, self-extinguishing
Working principle:
RFID
Frequency band:
125 kHz
Transmitter output:
max. -6 dBm
Coding level according to ISO 14119:
- I1-version:
high
- I2-version:
high
- Standard coding version:
low
Reaction time:
- Actuator:
≤ 100 ms
- Inputs:
≤ 0.5 ms
Duration of risk:
< 200 ms
Time to readiness:
< 4,000 ms
Series-wiring:
Unlimited number of components,
please observe external cable protection,
max. 31 components in case of serial diagnostics
Cable length:
max. 200 m
(cable length and cable section alter the voltage
drop depending on the output current)
Mechanical data
Holding force F
max
:
2,600 N (1,300 N when used with the
AZ/AZM201-B30 actuator, for indoor use)
Holding force F
Zh
:
2.000 N (1.000 N when used with the
AZ/AZM201-B30 actuator, for indoor use)
Latching force:
30 N
Termination:
Screw terminals or cage clamps,
Connector plug M12
Cable entry:
M20
Cable type:
rigid single-wire, rigid multi-wire or flexible
Cable section:
min. 0.25 mm², max. 1.5 mm²
(including conductor ferrules)
Tightening torque for the cover screws:
0.7 ... 1 Nm (Torx T10)
Actuating speed:
≤ 0.2 m/s
Mechanical life:
≥ 1,000,000 operations
Ambient conditions
Ambient temperature:
−25 °C … +60 °C
Storage and transport temperature:
−25 °C … +85 °C
Relative humidity:
max. 93 %,
non condensing, non icing
Protection class:
IP66, IP67 to IEC 60529
Protection class:
III
Resistance to shock:
30 g / 11 ms
Resistance to vibration:
10 … 150 Hz, amplitude 0.35 mm
Insulation values to IEC 60664-1:
- Rated insulation voltage Ui:
32 VDC
-
Rated impulse withstand voltage Uimp:
0.8 kV
-
Over-voltage category:
III
-
Degree of pollution:
3
Switching frequency:
≤ 1 Hz
Electrical Data
Operating voltage U
B
:
24 VDC −15% / +10%
(stabilised PELV power supply)
Power consumption device:
≤ 0.05 A
Operating current device with magnet switched on:
- Averaged:
< 0.2 A
- Peak current:
< 0.7 A / 100 ms
Required rated short-circuit current:
100 A
External device fuse rating:
- Screw terminals or cage clamps:
≤ 4 A when used
in accordance with UL 508,
- Connector plug M12:
≤ 2 A
Electrical data - Safety inputs
Safety inputs:
X1 and X2
Switching thresholds:
−3 V … 5 V (Low)
15 V … 30 V (High)
Current consumption per input:
typically 2 mA / 24 V
Accepted test pulse duration on input signal:
≤ 1.0 ms
- With test pulse interval of:
≥ 100 ms
Classification:
ZVEI CB24I
Sink:
C1
Source:
C1
C2
C3
Electrical data - Safety outputs
Safety outputs:
Y1 and Y2
Switching elements:
OSSD, p-type, short-circuit proof
Utilisation category:
DC-13: Ue/Ie: 24 VDC / 0.25 A
Rated operating current I
e
:
each max. 0.25 A
Leakage current I
r
:
≤ 0.5 mA
Voltage drop U
d
:
≤ 4 V
Cross-wire monitoring by device:
Yes
Test pulse duration:
< 0.5 ms
Test pulse interval:
1,000 ms
Classification:
ZVEI CB24I
Source:
C2
Sink:
C1
C2
Electrical data - Diagnostic output
Diagnostic output:
OUT
Switching element:
p-type, short-circuit proof
Utilisation category:
DC-13: U
e
/I
e
: 24 VDC / 0.05 A
Rated operating current l
e
:
max. depending 0.05 A
Voltage drop U
d
:
≤ 4 V
Serial diagnostic SD
Operating current:
0.15 A
Wiring capacitance:
max. 50 nF
Electrical data - Magnet control
Solenoid input:
IN
Switching thresholds:
−3 V … 5 V (Low)
15 V … 30 V (High)
Power consumption:
typical 10 mA / 24 V,
dynamic 20 mA
Duty ratio solenoid ED:
100 %
Accepted test pulse duration on input signal:
≤ 5.0 ms
- With test pulse interval of:
≥ 40 ms
Classification:
ZVEI CB24I
Sink:
C0
Source:
C1
C2
C3
Use isolated power supply only.
For use in NFPA 79 Applications only.
Adapters providing field wiring means are available from
the manufacturer. Refer to manufacturers information.
This device complies with part 15 of the FCC Rules and contains
licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s licence-exempt
RSS(s):
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
This device complies with the Nerve Stimulation Exposure Limits
(ISED SPR-002) for direct touch operations.
Changes or modifications not expressly approved by K.A. Schmersal
GmbH & Co. KG could void the user's authority to operate the
equipment.
L’émetteur/récepteur exempt de licence contenu dans le présent
appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes :
(1) L’appareil ne doit pas produire de brouillage.
(2) L’appareil doit accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d’en compromettre le fonctionnement.
Cet appareil est conforme aux limites d'exposition relatives à la
stimulation des nerfs (ISED CNR-102) pour les opérations tactiles
directes.
Changements ou modifications non expressément approuvés par K.A.
Schmersal GmbH & Co. KG pourrait annuler le droit de l'utilisateur à
utiliser l'équipement.