3.2 Manual release
For the machine set-up, the solenoid interlock can be unlocked in a de-energised condition. The solenoid interlock is
unlocked by turning the manual release in the position
q
The normal locking function is only restored after the
manual release has been returned to its original position
p
.
Caution: do not turn beyond the end stop!
Key
A: connector plug M12, 8-pole
B: LED display
C1: Manual release by means of slotted screwdriver
C2: Manual release by means of triangular key TK-M5
The manual release must be protected against accidental actuation, e.g. by using the enclosed seal after
completing commissioning.
3.3 Emergency exit -T/-T8 or emergency release -N
With variants that have both emergency exit and emergency release, the red lever is loosely supplied. Before first
use, mount the lever on the triangular part of the release using the screw supplied so that the arrow in the triangle
and pin on the red lever are congruent.
The installation of the lever is possible on both sides. The opposite side can be used as a manual release by means
of a triangular key TK-M5.