2
Reset of the manual release by actuating the red emergency exit lever must be prevented by the user.
2
Emergency exit (-T/-T8)
(fitting and actuation only from within the hazardous area)
To activate the emergency exit, turn the red lever in the direction of the arrow to the end stop. The safety outputs
switch off and the guard system can be opened. The blocked position is cancelled by turning the lever in the
opposite direction. In the unlocked position, the guard system is secured against unintentional locking.
2
Emergency release (-N)
Fitting and actuation only from outside the hazardous area. The emergency release should only be
used in an emergency. The solenoid interlock should be installed and/or protected so that an
inadvertent opening of the interlock by an emergency release can be prevented. The emergency
release must be clearly labelled that it should only be used in an emergency. The label can be used
that was included in the delivery.
To activate the emergency release turn the red lever in the direction of the arrow to the end stop. The safety
outputs switch off and the guard system can be opened. The lever is latched and cannot be returned to its original
position. To cancel the blocking condition, the central mounting screw must be loosened to such extent that the
lever can be turned back into its original position. The screw must then be re-tightened.
F
To ensure correct operation of emergency exit -T/-T8 and emergency release -N, the safety door/guard
must not be in a mechanically tensioned state.
2
It is possible to combine an emergency exit with an emergency release. Please note that when the red
lever is actuated, the opposite lever also rotates. As such, the procedure outlined above must be
followed to release the emergency release lever.
3.4 Mounting with mounting plate
For doors, which close flush with the door frame, the optional mounting late MP-AZ/AZM300-1 can be used.