DIA_PRO_CUR_kazm3d01-04
Image not found or type unknown
Safety guard can be locked
DIA_PRO_CUR_kazm3d01-05
Image not found or type unknown
Safety guard locked
Table 1: Diagnostic information of the safety switchgear
System
condition
Magnet control
IN
LED
Safety outputs Y1,
Y2
Diagnostic
output OUT
Power
to
unlock
Power
to lock
green
red
yellow
AZM300Z AZM300B
Safety guard open
24 V (0
V)
0 V (24
V)
On
Off
Off
0 V
0 V
0 V
Safety guard
closed,
not locked
24 V
0 V
On
Off
Flashes
0 V
24 V
24 V
Safety guard
closed,
locking
impossible
0 V
24 V
On
Off
Flashes
0 V
24 V
0 V
Safety guard
closed and locked
0 V
24 V
On
Off
On
24 V
24 V
24 V
Error warning
1)
0 V
24 V
On
Flashes
2)
On
24 V
1)
24 V
1)
0 V
Error
0 V (24
V)
24 V (0
V)
On
Flashes
2)
Off
0 V
0 V
0 V
No input signal at
X1 and/or X2
0 V (24
V)
24 V (0
V)
Flashes
Off
Off
0 V
0 V
0 V
No input signal at
X1 and/or X2
0 V (24
V)
24 V (0
V)
Flashes
Off
On/Flashes
0 V
0 V
24 V
Additionally for variant I1/I2:
Teach-in procedure
actuator started
Off
Off
Flashes
0 V
0 V
0 V
Only I2: teach-in
procedure actuator
(release block)
Flashes
Off
Off
0 V
0 V
0 V