Storage and transport temperature, minimum
-10 °C
Storage and transport temperature, maximum
+90 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing
non-icing
Resistance to vibration to EN 60068-2-6
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level,
maximum
2,000 m
Ambient conditions - Insulation values
Rated insulation voltage U
i
32 VDC
Rated impulse withstand voltage U
imp
0.8 kV
Overvoltage category
III
Degree of pollution to IEC/EN 60664-1
3
Electrical data
Operating voltage, minimum
20.4 VDC
Operating voltage, maximum
26.4 VDC
Note (Power supply, general)
stabilised PELV power supply
No-load supply current I
0
, maximum
100 mA
Current consumption with magnet ON, average
200 mA
Current consumption with magnet ON, peak
350 mA / 200 ms
Required rated short-circuit current to EN 60947-5-1
100 A
External wire and device fuse rating
2 A gG
Switching frequency, maximum
0.5 Hz
Electrical data - Magnet control
Switching thresholds
-3 V … 5 V (Low)
15 V … 30 V (High)
Current consumption at 24V
10 mA
Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0