background image

6

Operating instructions

Solenoid interlock

AZM400

EN

3.6  Dimensions

All measurements in mm.

AZM400Z-ST

AZM400Z-ST2

77.8

63

7.4

23.8

11.7

145

12

20

C1

A1

B

77.8

63

7.4

23.8

30

11.7

145

12

20

C1

C2

24.3

44.8

46.7

D

Device for emergency exit

AZM400Z-ST..-T

AZM400Z-ST2..-T

77.8

63

7.4

23.8

11.7

145

12

20

A2

77.8

63

7.4

23.8

30

11.7

145

12

20

24.3

44.8

65.3

Key

A1: Manual release with cover

C1: Connector plug M12, 8-pole

A2: Emergency exit

C2: Connector plug M12, 5-pole

B:

Locking bolt (extended)

D:

RFID sensor

3.7  Actuator and accessories

Actuator AZM400-B1 (not included in delivery)

63

63

7.4

77.8

30

12

24.3

44.8

Mounting plate, part of the mounting set MS-AZM400

(available as accessory)

5

40

120

100

26

6.6

3.5x45°

11.5

63

¤6.6

7

Lockout tag SZ400

(available as accessory)

For detailed information and assembly instructions, see operating 

instructions SZ400.

Bowden cable release ACC-AZM400-BOW-.M-.M 

Observe the additional notes in the operating instructions of the 

Bowden cable release.

Summary of Contents for AZM400

Page 1: ...ine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range...

Page 2: ...release fitted is not permissible Observe the additional information in the operating instructions of the Bowden cable release 2 2 Special versions For special versions which are not listed in the or...

Page 3: ...en max 0 6 A Required rated short circuit current 100 A External Device fuse rating 2 A Min open close cycle Motor 3 s with continuous operation min average cycle time 20 s Electrical data Safety outp...

Page 4: ...lenoid interlock 1 7 mm with max angle offset of 2 The actuating curves show the typical detection range of the actuator depending on the actuating direction 26 10 26 10 0 mm 0 18 18 mm X Y 1 7 mm 4mm...

Page 5: ...auxiliary power supply this is so the locking bolt can be released independently of the control inputs Then no other actions are required the safety and diagnostic units remain off System condition on...

Page 6: ...C1 Connector plug M12 8 pole A2 Emergency exit C2 Connector plug M12 5 pole B Locking bolt extended D RFID sensor 3 7 Actuator and accessories Actuator AZM400 B1 not included in delivery 63 63 7 4 77...

Page 7: ...cable Minimum test interval every 24 hours etc Block drive If the locking bolt does not reach the locked condition with the first attempt the AZM400 makes an autonomous attempt If the second attempt...

Page 8: ...this way the activated code is definitively saved For ordering suffix I1 the executed allocation of safety interlock and actuator is irreversible For ordering suffix I2 the teach in procedure for a n...

Page 9: ...Unlock Off On Flashes quickly 0 V 0 V 0 V 0 V Only I2 Actuator has been taught Manipulation protection time is running Unlock Flashes Off Off 0 V 24 V 0 V 24 V 1 after 30 min disabling due to fault 2...

Page 10: ...nance In the case of correct installation and adequate use the safety switchgear features maintenance free functionality A regular visual inspection and functional test including the following steps i...

Page 11: ...r codes for more commercially available connectors based on IEC 60947 5 2 2007 OUT2 Diagnostic output 2 1 WH BN E1 Control input 1 2 BN WH Not connected 3 GN BU Y1 Safety output 1 4 YE BK OUT1 Diagnos...

Page 12: ...ype test certificate 01 205 5467 00 15 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG M ddinghofe 30 D 42279...

Reviews: