104
Installation manual of system “bp408” - Commissioning
8.11.2
Basic settings
After installing the absolute encoder system (see attached installation description),
the following default settings must be carried out on the bp408 in the setup menu:
Setup menu:
> PARAMETERS
> LIFT DATA
> COPYING TOOL > ABSOLUTE ENCODER (CAN)
next:
> PARAMETERS
> COPYING TOOL
> AWG1 PARAMETERS
> ENCODER SYSTEM
or
> USER-DEFINED
Deceleration points and levelling positions can be comfortably changed via setup
menus.
In the service menu, the following basic settings must be carried out:
Service menu:
> SETTING
> FUNCTIONS
> DRIVE
> DRIVE SPEED
> BRAKING DISTANCE
> MINIMUM DRIVE DISTANCES
Here, enter the nominal and intermediate speeds of the system.
Further in the menu:
> SETTING
> DISTANCE MEASUREMENT
> PARAMETERS
> GENERAL DISTANCES
SHAFT PIT
SHAFT HEAD
CAR HEIGHT
The approximate shaft pit depth must be specified. This is the distance between
the threshold of the lowest floor and the shaft bottom. This value is set to 1 m by
default and serves for receiving the image of the shaft as accurately as possible.
Summary of Contents for bp408
Page 2: ......
Page 24: ...24 Installation manual of system bp408 Safety instructions...
Page 52: ...52 Installation manual of system bp408 The control system bp408...
Page 58: ...58 Installation manual of system bp408 Installation and assembly...
Page 80: ...80 Installation manual of system bp408 Electrical connection...
Page 118: ...Installation manual of system bp408 Appendix 118 Appendix A Menu navigation bp408...
Page 119: ...119 Installation manual of system bp408 Appendix B Update of the firmware via USB stick...