82
Installation manual of system “bp408” - Commissioning
8.1.1
Before first switch-on
According to VDE 0100 and EN 81, the power circuit must be earthed. The terminal
“PE” of the control system is therefore always connected to the power supply via a
green / yellow cable.
8.2
Technical information about the control system
1. Smooth and safe operation of the product requires proper transport, storage,
setup and assembly as well as careful operation and maintenance.
2. The control system is designed, built and checked according to DIN EN 81
and VDE regulations. You must follow the relevant regulations for
commissioning electric control devices and equipment. The local lightening
protection measures are a prerequisite for operation. Circuit diagrams
uniquely marked with a controlling number and technical documents are part
of every control system.
3. The control system bp408 exclusively helps for information processing in a lift
control system. All control signals are processed with positive switching logic.
The safety guidelines of DIN EN 81 are not restricted by electronic information
processing.
4. The control system bp408 has received an EU-type examination certificate
from notified bodies. Section 3.1 lists the EU type examination certificate and
chapter 3.3 the EU declaration of conformity within the meaning of EU
Directive (2014/33 / EU), which shows that the assembly we use complies with
the regulations.
5. The components used in the control systems comply with DIN EN 81 as well
as VDE 0100 / 0101 / 0551 / 0660 and BGV A2. The control cabinets comply
with the installation standard VDE 0660 / part 500.
6. The main and auxiliary contactors used in the control systems comply with
DIN EN 81-20, 5.10.3 and VDE 0660, but at least device class D3.
7. Voltage fluctuations that are within the tolerance range (+10%; -20%) of
energy supply companies (RUs) are permissible.
8. Faults caused by an impermissible increase in voltage cannot lead to claims
for damages against the manufacturer.
9. Special features when using an uninterruptible power supply (UPS) must be
observed. Before commissioning the connected UPS, read the operation
manual. The UPS must ensure supply to all necessary control functions.
Summary of Contents for bp408
Page 2: ......
Page 24: ...24 Installation manual of system bp408 Safety instructions...
Page 52: ...52 Installation manual of system bp408 The control system bp408...
Page 58: ...58 Installation manual of system bp408 Installation and assembly...
Page 80: ...80 Installation manual of system bp408 Electrical connection...
Page 118: ...Installation manual of system bp408 Appendix 118 Appendix A Menu navigation bp408...
Page 119: ...119 Installation manual of system bp408 Appendix B Update of the firmware via USB stick...