EFAS CAM-Creator
DOC_MAN_MEC_EFAS-CAM_#SEN_#AIN_#V1
Seite 44 von 56
Version: 2018 / 02
6.4.4.4 Dead-Time (Control/Options/[Modul x]/Dead-Time)
Sets the limits and effects of dead time compensation.
Go to Control/Dead-Times to separately set the dead times of each track (6.4.1 Dead-Times).
Dead times are computed cyclically; section 6.4.4.1 explains how to set the cycle time for computation.
Enabled:
Tick this box to enable dead time compensation.
Mode :
Dead time compensation mode
cyclic
cyclic calculation of dead times,
i.e. after every clock pulse (see Options/Encoder/Cycle-Time; 6.4.4.1 Encoder)
in the range
(currently not implemented).
Range behind CAM No.
Dead time calculation in the range after cam no.
synchronized
(currently not implemented).
All dead times are calculated at the zero point
Range behind CAM
Dead time calculation in the range after cam no. x.
Range … of … up.
Dead time calculation in the range from ... to ... ticks after the cam selected above.