Operating instructions
Safety switch

EX-AZ 3550

EN

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded when safety switchgear is 
used. The relevant requirements of the standard ISO 14119 
must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages resul-
ting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

EX-AZ 3350-

-

-3D

No.

Option

Description

03-ZK

3 NC

12-ZUEK

1 NO contacts / 2 NC contacts

1637

Gold-plated contacts

Only if the information described in this operating instruc-
tions manual are realised correctly, the safety function and 
therefore the compliance with the Machinery Directive and 
the Explosion Protection Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The safety switches are suitable for sliding, hinged and removable sa-
fety guards, which need to be closed in order to ensure the necessary 
operational safety.

 The components can be used in explosion-endangered areas of Zone 
22 equipment category 3D.  The installation and maintenance require-
ments to the standard series EN 60079 must be met.

The user must evaluate and design the safety chain in ac-
cordance with the relevant standards and the required safety 
level.

Conditions for safe operation

Due to their specific impact energy, the components must be fitted with 
a protection against mechanical stresses. The specific ambient tempe-
rature range must be observed.

2.4  Technical data

Equipment category: 

II 3D

Ex protection:

 

Ex tc IIIC T90°C Dc X

Standards:

 

IEC 60947-5-1, EN 60079-0,  
EN 60079-31, BG-GS-ET-15

Enclosure:

 

light-alloy diecast, paint finish

Actuator:

 VA

Design:

 

EN 50041

Max. impact energy:

 

4 J

Actuating speed:

 

max. 1 ms 

Switching frequency:

 

1200 / h

Protection class: 

IP67 to IEC 60529

Contact material:

 Silver

Contact type: 

change-over with double break Zb,  

or 3 NC contacts, galvanically separated contact bridges

Switching system:

 

A

 IEC 60947-5-1; slow action,  

NC contact with positive break

Connection:

 

screw terminals

Cable section: 

min. 0.75 mm², max. 2.5 mm²  

(including conductor ferrules)

Cable entry:

 

M20 x 1.5

Rated impulse withstand voltage U

imp

:

 

4 kV

Rated insulation voltage U

i

:

 

250 V

Thermal test current I

the

:

 

10 A

Utilisation category:

 

AC-15 / DC-13

Rated operating current/voltage I

e

/U

e

:

 

4 A / 230 VAC  

4 A / 24 VDC

Max. fuse rating:

 

6 A gG D-fuse

Positive break travel:

 

10.7 mm

Positive break force:

 

each NC contact 5 N 

Ambient temperature: 

− 10°C … + 60°C

Mechanical life: 

> 1 million operations

Cable cross-section of the cable glands:

 

min. Ø 7 mm;  

max. Ø 12 mm;  

L

 II 2GD

Tightening torque:

 

 Cable gland: min.1.0 Nm 

Cover screws: min. 8 Nm

2.5  Safety classification

Standards: 

ISO 13849-1

B

10d

 (NC  contact):

 2.000.000

B

10d

 (NO contact)  

at 10% ohmic contact load:

 1,000,000

Service life: 

20 years

MTTF

B

d

x

x

h

s/h

3600

d

10d

op

op

op

n

0,1 x n

op

t

cycle

(Specifications can vary depending on the application-specific parame-
ters h

op

, d

op

, t

cycle

 as well as the load.)

mrl_ex-az3350_en.indd   6

04.03.2015   08:33:28

Summary of Contents for EX-AZ 3350 Series

Page 1: ...er technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet www schmersal net The information contained in this operating instructions manual is provi ded without liability and is subject to technical modifications There are no residual risks provided that the safety instructions as well as the instructions regarding mounting commissioning operation...

Page 2: ...ion endangered areas of Zone 22 equipment category 3D The installation and maintenance require ments to the standard series EN 60079 must be met The user must evaluate and design the safety chain in ac cordance with the relevant standards and the required safety level Conditions for safe operation Due to their specific impact energy the components must be fitted with a protection against mechanica...

Page 3: ...ty guard closed 1 NO contacts 2 NC contacts 3 NC 13 21 31 14 22 32 A A A 11 21 31 12 22 32 5 Set up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met The installation is executed according to the instructions The connection is executed correctly The cable is correctly executed and connected...

Page 4: ...for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal December 9 2014 Authorised signature Philip Schmersal Managing Di...

Reviews: