Operating instructions
Passive distribution module

PDM-IOP-4CC-IOP

EN

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages 
resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 
repairs, conversions and modifications to the device are strictly 
forbidden; the manufacturer shall accept no liability for damages 
resulting from such invasive work, arbitrary repairs, conversions and/or 
modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

PDM-IOP-4CC-IOP

Option

Description

PDM

Passive distribution module

IOP

Evaluation side: IO parallel

4CC

4 device connections with cage clamps

IOP

Device connection: IO parallel

2.2  Destination and use

The PDM-IOP-4CC-IOP passive distribution module is designed for the 
connection of 4 electronic safety switchgear units with parallel  
IO signals manufactured by SCHMERSAL. It serves to connect up to 4 
safety switchgear units in series.
To increase the safety functionality, more passive distribution modules 
can also be connected in series.

CSS 30- and CSS 180-type devices cannot be used on this 
module.

With the PDM-IOP-4CC-IOP passive distribution module, the secure 
OSSD outputs of the connected safety switchgear units are connected 
in series and wired to a relevant safety-monitoring module.

The non-secure IO signals of the devices are wired in parallel to a 
control system.

The user must evaluate and design the safety chain in 
accordance with the relevant standards and the required 
safety level.

2.3  Technical data

Standards:

 

IEC 60947-1

Material of housing:

 Plastic, 

polyamide

 66

Mounting:

 

35 mm standard rail in  

accordance with EN 60715

Mechanical data 

Type of connection:

 

Clips, cage clamps

Cable section:

 

min. 0.25 mm², max. 1.5 mm²  

(including conductor ferrules)

De-insulation length:

 

5 … 6 mm

Actuator tool blade:

 

3.5 x 0.5 mm

Ambient conditions 

Ambient temperature:

 

−25 °C … +65 °C

Storage and transport temperature:

 

−40 °C … +85 °C

Relative humidity:

 

5 % … 95 %,  

non condensing

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

10 ... 55 Hz,  

amplitude 1 mm

Protection class:

 

IP00 to IEC 60529

Protection class:

 III

Insulation values to IEC 60664-1: 

 

- Rated insulation voltage Ui:

 

32 VDC 

- Rated impulse withstand voltage U

imp

:

 

0.8 kV 

- Over-voltage category:

 III 

- Degree of pollution:

 2

Electrical data 

Supply voltage U

B

:

 

24 VDC -15% / +10% 

 

(stabilised PELV mains unit)

Rated operating voltage U

e

 

24 VDC

Operating current I

e

 

- Distribution module (external fuse needed):

 

10 A  

- Device connection (internal fuse fitted):

 

1.5 A

Device connection line fuse:

 

Automatically resetting  

fuse element 1.5 A

LED indications 

Green “Power” LED:

 

Distribution module supply voltage

Green “F4” LED:

 

Device connection 4 fuse element

Green “F3” LED:

 

Device connection 3 fuse element

Green “F2” LED:

 

Device connection 2 fuse element

Green “F1” LED:

 

Device connection 1 fuse element

Summary of Contents for PDM-IOP-4CC-IOP

Page 1: ...nufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in thi...

Page 2: ...e secure OSSD outputs of the connected safety switchgear units are connected in series and wired to a relevant safety monitoring module The non secure IO signals of the devices are wired in parallel t...

Page 3: ...ed condition It is possible to connect wires with and without conductor ferrules with a wire cross section of 0 25 mm to 1 5 mm to the terminals of the passive distribution module The supply voltage o...

Page 4: ...pin device connection Pin assignment of safety switchgear connection Function safety switchgear Pin assignment of connector plug or conductor numbers Colour code of the Schmersal connector to DIN 4710...

Page 5: ...1 24 VDC device supplied I Solenoid control O Diagnostic output A2 0 VDC device supplied X1 Safety input 1 X2 Safety input 2 Pin assignment of safety switchgear 2 Y1 Safety output 1 Y2 Safety output 2...

Page 6: ...I2 I1 A1 A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 Safety IN 2 Safety IN 1 0 VDC 24 VDC IN 9 IN 8 IN 7 IN 6 OUT 9 OUT 8 OUT 7 OUT 6 10A O N 1 8 7 6 5 4 3 2 IN 5 IN 4 OUT 5 OUT 4 IN 3 IN 2 IN 1 OUT 3 OUT 2 OUT 1...

Page 7: ...O3 O2 O1 I4 I3 I2 I1 A1 A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 Y2 Y1 A2 A1 O4 O3 O2 O1 I4 I3 I2 I1 A1 A2 X1 X2 A1 A2 X1 X2 I O Y1 Y2 O N 1 8 7 6 5 4 3 2 O N 1 8 7 6 5 4 3 2 1 2 1 2 3 Module in middle SW 7 8...

Page 8: ...ntenance If installed correctly and used as intended the passive distribution module requires no maintenance 6 Disassembly and disposal 6 1 Disassembly The passive distribution module may only be remo...