background image

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning for the safe operation 
and disassembly of the input expander module. The operating instruc-
tions must be available in a legible condition and a complete version in 
the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operat-
ing instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards to 
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machinery or plant.

The input expander module must be exclusively used in accordance 
with the versions listed below or for the applications authorised by the 
manufacturer. Detailed information regarding the range of applications 
can be found in the chapter "Product description".

To avoid EMC disturbances, the physical ambient and 
operational conditions at the place where the product is ins-
talled, must meet the provisions laid down in the paragraph 
"Electromagnetic Compatibility (EMC)" of DIN EN 60204-1.

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the online  
catalogue on the Internet: www.schmersal.net.

The information contained in this operating instructions manual is pro-
vided without liability and is subject to technical modifications.

If multiple safety components are wired in series, the Perfor-
mance Level to EN ISO 13849-1 will be reduced due to the 
restricted error detection under certain circumstances. The 
entire concept of the control system, in which the safety com-
ponent is integrated, must be validated to EN ISO 13849-2.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 

Safety classiication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3

Operating principle and settings

5.1  LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2  Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 

Sensor coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

8.3 

Actuator coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Declaration of conformity

9.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

x.000 / 

August 2013 / v

.A.   -   101

183191-EN / E / 2012-04-26 / 

AE-Nr

. 2599

PROTECT-IE

Operating instructions
Input expander module

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Translation of the original operating instructions

Summary of Contents for PROTECT-IE Series

Page 1: ... product is ins talled must meet the provisions laid down in the paragraph Electromagnetic Compatibility EMC of DIN EN 60204 1 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can be ...

Page 2: ...control cabinets They are used for the evaluation of the signals of 1 4 sensors and the summarised transmission of the signals to a downstream safety monitoring module The function is defined as the opening of the enabling contacts 13 14 and 23 24 when one or more of the 8 sensor inputs are actuated The enabling paths with the outputs contacts 13 14 and 23 24 meet the following requirements under ...

Page 3: ...s described in this manual 3 Mounting 3 1 General mounting instructions Mounting snaps onto standard DIN rails to EN 60715 Snap the bottom of the enclosure slightly tilted backwards in the DIN rail and push down until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D 126 48 61 mm with plug in terminals 126 48 53 mm 4 Electrical connection 4 1 General information ...

Page 4: ...K1 K1 K2 K2 14 24 S6 13 23 A1 S4 S5 Y3 UB S7 S8 Y1 Y2 K1 K2 K3 K4 K5 K6 K7 K8 K1 K3 K5 K7 K2 K4 K6 K8 Protect IExx S12 S11 S22 S21 14 13 24 23 a Fig 3 a Safety monitoring module e g SRB 301MC SRB 301ST SRB 211ST 8 2 Sensor configuration Dual channel control of magnetic safety sensors to IEC 60947 5 3 see Fig 4 The control system recognises wire breakage and earth faults in the control circuit Cros...

Page 5: ...used inputs S2 S4 S6 and S8 remain vacant S1 S2 Y1 a S3 S4 Y2 S5 S6 Y3 S7 S8 Y4 Fig 9 a signal outputs 8 3 Actuator configuration Enabling circuits Fig 10 All safety monitoring modules with control category 4 or PLe from the Schmersal Group with current 1 A in the monitoring circuit can be connected to the Protect IE 02 and Protect IE 11 devices 13 23 14 24 S11 S21 S12 S22 13 23 14 24 a Protect IE...

Page 6: ... body which approved the full quality assurance system referred to in Appendix X 2006 42 EC TÜV Rheinland Industrie Service GmbH Alboinstraße 56 12103 Berlin ID n 0035 K A Schmersal GmbH Co KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www sch...