1.6  Warning about misuse

In case of inadequate or improper use or manipulations of 
the component, personal hazards or damage to machinery or 
plant components cannot be excluded. The relevant require-
ments of the standards EN 1088 and EN ISO 13850 must be 
observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

PROTECT-IE

-

No.

Option

Description

02

Connection of NC/NC sensors

11

Connection of NC/NO sensors

with cage clamps

SK

with plug-in screw connection

•  Possibility to connect up to 4 sensors per interface, 

 

e.g. safety magnetic switches of the BNS type, emergency 
stop control devices, interlocking devices, etc.

• Current and voltage limitation of the input circuits

• Cross-wire monitoring of the input circuits

•  Signalling output for each sensor (monitoring of both 

 

circuits of the sensors)

• Green LED indications for UB and every sensor contact

• Cascading possible for the connection of up to 80 sensors

This device is designed as input expander module. The  
safety function is only realised in conjunction with the 
downstream basic device (SRB). To this effect, the device 
must be connected in accordance with the wiring example!

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The input expander modules for integration in safety circuits are 
designed for fitting in control cabinets. They are used for the evaluation 
of the signals of 1...4 sensors and the summarised transmission of the 
signals to a downstream safety-monitoring module.

The function is defined as the opening of the enabling contacts 13-14 
and 23-24 when one or more of the 8 sensor inputs are actuated. The 
enabling paths with the outputs contacts 13-14 and 23-24 meet the 
following requirements under observation of a PFH value assessment 
and in conjunction with an SRB (control category 4 / PLe) (also refer to 
chapter 2.5 "Safety classification"):
–  Control category 3 – PL d to EN ISO 13849-1  

(when multiple safety guards are opened within one work cycle)

– SIL 2 to IEC 61508
–  SILCL 2 to EN 62061

refer to folder:
http://www.schmersal.net/Bilddata/broschue/k-info/i_diap01.pdf  
(german)
http://www.schmersal.net/Bilddata/broschue/k-info/i_diap02.pdf  
(english)

The above-described requirements cannot be met by the 
input expander module solely, but only in combination with  
a safety-monitoring module as described in this manual.

To determine the Performance Level (PL) to EN ISO 13849-1 of the 
entire safety function (e.g. sensor, logic, actuator), an assessment of all 
relevant components is required.

2.4  Technical data
General data:

Standards:

 

IEC/EN 60204-1, EN 60947-5-1;  

EN ISO 13849-1, IEC/EN 61508

Climate resistance:

 

EN 60068-2-78

Mounting:

 

Snaps onto standard DIN rail to EN 60715

Terminal designations:

 

EN 60947-1

Material of the housings:

 

thermoplastic plastic

Material of the contacts:

 AgNi

Weight:

 

140 g

Start conditions:

 Automatic

Feedback circuit (Y/N):

 No

Pull-in delay:

 

≤ 20 ms

Drop-out delay:

 

≤ 20 ms

Mechanical data: 

Connection type:

 

Cage clamps;  

- SK variant: 

plug-in screw connection

Cable section: 

 

- Cage clamps:

 

min. 0.08 mm² / max. 2.5 mm²

  

- Screw connection:

 

min. 0.14 mm² / max. 1.5 mm²

Connecting cable:

 

rigid or flexible

Tightening torque for the terminals: 

 

0.6 Nm

With removable terminals (Y/N):

 No; 

 

SK variant: Yes

Mechanical life:

 

10 million operations

Electrical life: 

 

Derating curve available on request

Resistance to shock:

 

30 g / 11 ms

Resistance to vibrations to EN 60068-2-6:

 

10 … 55 Hz,  

amplitude 0.35 mm

Ambient conditions: 

Ambient temperature:

 

−25 °C … +55 °C

Storage and transport temperature:

 

−40 °C … +85 °C

Protection class:

 IP20

Air clearances and creepage  

 

distances to IEC/EN 60664-1:

 

800 V/2 (basic insulation)

EMC rating: 

 

to EMC Directive

Electrical data: 

Contact resistance in new state: 

 

max. 100 mΩ

Power consumption:

 

max. max. 1.7 W plus Y1-Y4

Rated operating voltage U

e

:

 

24 VDC −15% / +20%, 

 

residual ripple max. 10%

Fuse rating for the operating voltage:

 

Internal electronic trip,  

tripping current > 100 mA

Summary of Contents for PROTECT-IE Series

Page 1: ... product is ins talled must meet the provisions laid down in the paragraph Electromagnetic Compatibility EMC of DIN EN 60204 1 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can be ...

Page 2: ...control cabinets They are used for the evaluation of the signals of 1 4 sensors and the summarised transmission of the signals to a downstream safety monitoring module The function is defined as the opening of the enabling contacts 13 14 and 23 24 when one or more of the 8 sensor inputs are actuated The enabling paths with the outputs contacts 13 14 and 23 24 meet the following requirements under ...

Page 3: ...s described in this manual 3 Mounting 3 1 General mounting instructions Mounting snaps onto standard DIN rails to EN 60715 Snap the bottom of the enclosure slightly tilted backwards in the DIN rail and push down until it latches in position 3 2 Dimensions All measurements in mm Device dimensions H W D 126 48 61 mm with plug in terminals 126 48 53 mm 4 Electrical connection 4 1 General information ...

Page 4: ...K1 K1 K2 K2 14 24 S6 13 23 A1 S4 S5 Y3 UB S7 S8 Y1 Y2 K1 K2 K3 K4 K5 K6 K7 K8 K1 K3 K5 K7 K2 K4 K6 K8 Protect IExx S12 S11 S22 S21 14 13 24 23 a Fig 3 a Safety monitoring module e g SRB 301MC SRB 301ST SRB 211ST 8 2 Sensor configuration Dual channel control of magnetic safety sensors to IEC 60947 5 3 see Fig 4 The control system recognises wire breakage and earth faults in the control circuit Cros...

Page 5: ...used inputs S2 S4 S6 and S8 remain vacant S1 S2 Y1 a S3 S4 Y2 S5 S6 Y3 S7 S8 Y4 Fig 9 a signal outputs 8 3 Actuator configuration Enabling circuits Fig 10 All safety monitoring modules with control category 4 or PLe from the Schmersal Group with current 1 A in the monitoring circuit can be connected to the Protect IE 02 and Protect IE 11 devices 13 23 14 24 S11 S21 S12 S22 13 23 14 24 a Protect IE...

Page 6: ... body which approved the full quality assurance system referred to in Appendix X 2006 42 EC TÜV Rheinland Industrie Service GmbH Alboinstraße 56 12103 Berlin ID n 0035 K A Schmersal GmbH Co KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www sch...

Reviews: