Description
In the case of a closed guard (I010) the interlocking solenoid (Q00A/Q00B) is acti-
vated if no error of the solenoid (M001) has been detected beforehand and no re-
quest to open the guard has been recognised. After a waiting period of 200ms for
the mechanical actuation realised by timer T0001, the guard must be interlocked
(contact I011 = true(1)). If this is not the case, T001 becomes true(1) and thus also
flag M001 which then goes into self-holding. The self-hold of M001 can be can-
celled by flag M002.
I010
Q00A
Q00B
Q00B
Q00A
I011