Instruction Manual PROTECT-PSC
V 2.6R01 / 04.19
1
–4
1.3.2
Explanation of symbols
Safety warnings
Text passages with a STOP symbol contain important warnings which must be
heeded under all circumstances. Failure to heed these warnings may place the
controller in a state which no longer provides adequate protection for man and/or
machine. Please read through such text sections with particular care.
Warnings
A CAUTION sign gives you important information and warnings which guarantee
the trouble-free operation of the PROTECT-PSC when heeded. Failure to heed
these warnings does not restrict the safe operation of the PROTECT-PSC.
Information
This symbol indicates useful additional information intended to facilitate the
commissioning/servicing of the PROTECT-PSC or to provide a deeper insight into
the mode of operation of the controller.
Cross references
This symbol refers to other text passages within the document which contain
additional information. The first digit describes the chapter and the second the
page within the chapter.
Additional Information
This symbol refers to external literature containing additional information on a par-
ticular theme. You will find the exact title of the additional literature in the appendix
(Chapter 8.5) by means of the number beside the symbol.
1.4
Product description
The PROTECT-PSC is a modular programmable safety field bus controller. It
serves to monitor and control safety equipment. In connection with safety-
orientated sensors/actuators it complies with the Performance Level (PL) e, Cate-
gory 4 to ISO 13849-1. It can only be used in systems in which the safe state is
synonymous with a de-energized state. It can be used to replace virtually all
circuitry so far used in relay technology.
CPU module can control up to 15 Safety Input/Output modules and operational In-
put/Output modules (Maximum of 254 channels). But, only safety input/output
modules can not consist 15 modules. (In case of only consists of safety in-
put/output module, 14 modules maximum)
The PROTECT-PSC is intended for use in control circuits to IEC 60204 for a rated
voltage of 24 VDC. The appropriate shock-hazard protection requirements must be
met for the applications.
x.x.x / x-xx
x.x.x / xx
Summary of Contents for PROTECT-PSC
Page 4: ......
Page 8: ......
Page 112: ......
Page 132: ......
Page 252: ......
Page 265: ...Annex 8 Instruction Manual PROTECT PSC V 2 6R01 04 19 8 5 8 3 EC Type Examination certificate ...
Page 266: ...Annex 8 Instruction Manual PROTECT PSC V 2 6R01 04 19 8 6 8 4 Declarations of conformity W ...
Page 267: ...Annex 8 Instruction Manual PROTECT PSC V 2 6R01 04 19 8 7 8 5 Index ...