background image

8

Operating instructions
Safety-monitoring module

PROTECT SRB 101EXi-1R

EN

PROTECT

 SRB 101EXi-1R-D-EN

10. 

EC Declaration of conformity

The currently valid declaration of conformity can be down-
loaded from the internet at www.schmersal.net.

10.1 

EC Declaration of conformity

Name of the safety component:

SRB 101EXi-1R

L

 II 3 G Ex nA nC IIC T5 Gc

L

 II (2) G [Ex ib Gb] IIC  

L

 II (2) D [Ex ib Db] IIIC

Description of the safety component:

Safety-monitoring module for emergency stop 
circuits and guard door monitoring

Relevant EC-Directives:

2006/42/EC EC-Machinery Directive
94/9/EC EC-Explosion Protection Directive (ATEX)
2004/108/EC EMC-Directive

Used harmonized standards:

EN 60079-0, EN 60079-11, EN 60079-15

Person authorized for the compilation 
of the technical documentation:

Oliver Wacker
Möddinghofe 30
42279 Wuppertal

Notiied body:

TÜV Rheinland Industrie Service GmbH
Am Grauen Stein

51105 Köln

ID n°: 0035

Certiicate number: 01 220 4316/06

EC-prototype test certiicate:

TÜV 08 ATEX 7522

EC- test certiicate:

TÜV 08 ATEX 7557 X

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal 

Phone: 

+49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00
E-Mail: info@schmersal.com
Internet: http://www.schmersal.com

Place and date of issue:

Wuppertal, December 8, 2014

Authorised signature

Philip Schmersal

Managing Director

EC Declaration of conformity

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com

We hereby certify that the hereafter described safety components both in its basic design and construc-
tion conform to the applicable European Directives.

Translation  
of the original Declaration of Conformity

Summary of Contents for PROTECT SRB 101EXi-1R

Page 1: ...lusively used in accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter...

Page 2: ...y function is defined as the opening of release 13 14 when the inputs S11 S12 or S21 S22 are opened The safety relevant current path with output contact 13 14 meets the following requirements under ob...

Page 3: ...ions Mounting snaps onto standard DIN rails to EN 60715 Snap the bottom of the enclosure slightly tilted forwards in the DIN rail and push up until it latches in position 3 2 Mounting of the sensors T...

Page 4: ...1 A2 is ON and the fuse F1 has not been triggered 5 2 Description of the terminals Voltages A1 24 VDC A2 0 VDC Inputs S11 S12 Input channel 1 S21 S22 Input channel 2 S21 S22 Input channel 2 with cross...

Page 5: ...d condition only Push up the bottom of the enclosure and hang out slightly tilted for wards 7 2 Disposal The safety monitoring module must be disposed of in an appropriate manner in accordance with th...

Page 6: ...Fig 12 At least one contact with positive break required Wire breakage and earth leakage in the control circuits are detected Cross wire shorts between the control circuits are not detected For the sa...

Page 7: ...ding to IEC EN 60079 14 ABTN NBR IEC 60079 14 a declaration of the manufactu rer therefore can be used The devices classified as simple electrical apparatus can be used in the Zones 1 2 and 21 22 Only...

Page 8: ...lation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Notiied body T V Rheinland Industrie Service GmbH Am Grauen Stein 51105 K ln ID n 0035 Certiicate number 01 220 4316...