Mounting and wiring instructions /  
Safety relay module

for emergency stop monitoring and guard door monitoring

PROTECT 

SRB 200EXi-1R

2

0V S12

J

S11 S21 S22

K

B

K

A

K

A

K

B

K

A

K

B

K2

K1

A2

PA PA

N

14 24

S

Logic

Installation

up to

zone 2

Installation

up to 

zone 1/21

K1

K2

U

i

U

EXi

F1

F2

U

B

13

L1

23

A1

X1 X2

nQS

QS

2-channel selection shown by way of example 
of a guard monitoring with two position 
switches, of which at least one is positively 
opening; with external reset button 

J

.

Power level: 2-channel selection control, 
suitable for contact amplification or contact 
multiplication by means of contactor or relay 
with positive driven contacts.
Wire breaks, earth leakages and cross-shorts 
in the monitoring circuits are detected.

S

 = feedback loop

Safety function

The safety function is defined as follows: The 
enabling outputs 13-14/23-24 is open, when 
the inputs S11-S12 and/or S21-S22 opens.

The safety related current path with the output 
contacts 13-14 fulfil in consideration with a 
B

10d

-value view the following requirements 

(refer also to “Information within the meaning 
of DIN EN ISO 13 849-1”):

category 4 – PL e  

 

acc. DIN EN ISO 13 849-1:2007
is equivalent to SIL 3  

 

acc. DIN EN 61 508-2:2002
is equivalent to SILCL3  

 

acc. DIN EN 62 061:2005

(is equivalent to control category 4 
acc. DIN EN 954-1:1997)

For designation of the performance level (PL) 
acc. DIN EN ISO 13 849-1:2007 of the whole 
safety function (e.g. sensor, logic, actor) a view 
to all relevant components is necessary.

Type designation

SRB 200EXi-1R (installation of the sensors up 
to zone 1/21)

Enabling current paths: 2 NO

 

Operating voltage: 24 VDC

 

Order number: 1196284

 

Approvals: TÜV 08 ATEX 7522, 

 

TÜV 08 ATEX 7557X

Authorised applications

The applicable laws or guidelines for the use 
or the planned application are to be consid-
ered. The safety relay module is for use in:

Emergency stop circuits with control de-

 

vices to DIN EN ISO 13 850:2007,  
EN 60 947-5-5:2005
Guard door monitoring circuits with locking 

 

device to EN 1088:2007
Monitoring circuits with electromagnetic 

 

safety switches to EN 60 947-5-3:2005

U

EXi

U

B

U

i

K1

K2

SRB 

200EXi

   -1R

0V X1 X2

S11 S12 S21 S22

13 14 23 24

PA PA A1 A2

Summary of Contents for PROTECT SRB 200EXi-1R

Page 1: ...ideration with a B10d value view the following requirements refer also to Information within the meaning of DIN EN ISO 13849 1 category 4 PL e acc DIN EN ISO 13849 1 2007 is equivalent to SIL 3 acc DIN EN 61508 2 2002 is equivalent to SILCL3 acc DIN EN 62061 2005 is equivalent to control category 4 acc DIN EN 954 1 1997 For designation of the performance level PL acc DIN EN ISO 13849 1 2007 of the...

Page 2: ...x 20 ms Bypass in the case of voltage drops approx 15 ms Air clearance and creepage distance IEC 60664 1 2007 DIN VDE 0110 1 4 kV 2 basic isolation EN 60079 11 2007 VDE 0170 0171 Part 7 Class of protection housing IP 40 terminals IP 20 installation space IP 54 Cable connections Single core rigid or flexible with or without wire end ferrule 0 25 2 5 mm 2 Dual wire with same cross section rigid or f...

Page 3: ...1 2007 voltage peak value 375 V Group category II C II B External capacitance Co nF 26 36 46 49 160 180 230 280 350 412 External inductance Lo mH 4 0 2 0 1 0 0 5 38 0 5 0 2 0 1 0 0 5 0 2 Reference value of a circuit C 200 nF km L 1 mH km C 200 pF m L 1 µH m Mounting of the sensors The execution of the installation of the intrinsically safe circuits is to be realized according the up to date Europe...

Page 4: ... Connecting and disconnecting of contacts of not intrinsically safe circuits under potentially explosion atmosphere is not allowed The housing may only be cleaned with a wet cloth The life cycle of the module relating to the type of protection nC is at least 15 years After end of this time the module is to be changed or to be send to the manufacturer for a check up Attention The temperature declar...

Page 5: ...49 1 2007 reachable S12 S11 S22 S21 nQS QS E Stop Sensor configuration Dual channel emergency stop circuit with control devices acc DIN EN ISO 13850 2007 EN 418 and EN 60947 5 5 2005 Detects wire breaks and earth leakages in the control circuits Cross shorts between the control circuits are not detected For monitoring the safety circuits the emer gency stop control devices can be executed as simpl...

Page 6: ...ire breaks and earth leakages in the control circuits Cross shorts between the control circuits are detected For monitoring the safety circuits the emer gency stop control devices can be executed as simple apparatus Example devices refer to section Simple apparatus Categorie 4 PLe acc DIN EN ISO 13849 1 2007 reachable Sensor configuration Dual channel control with electro magnetic safety switches ...

Page 7: ...an be used as simple apparatus EX BN 20 3G D K A Schmersal GmbH EX BNS 33 3G D K A Schmersal GmbH EX BNS 120 3G D K A Schmersal GmbH EX BNS 180 3G D K A Schmersal GmbH EX BNS 303 3G D K A Schmersal GmbH without LED version Simple apparatus Installation instructions Application area acc ATEX directive Category 2G 3G Usage in gas explosion endangered areas of the zones 1 and 2 Category 2D 3D Usage i...

Page 8: ...the instal lation The distance of 6 mm between the terminals of the intrinsically safe circuits to other intrinsically safe circuits should be considered The distance of 50 mm between the terminals of the intrinsically safe circuits to other not intrinsically safe circuits should be considered The phasing of the enabling paths 13 14 23 24 may not be different i e only one phase may be connected to...

Page 9: ... Applikationen mit potenzialbehafteten Ausgängen in den Ansteuerkreisen Pos QS unten Querschlusssicher geeignet für zweikanalige Applikationen ohne potenzialbehaftete Aus gänge in den Ansteuerkreisen Achtung Bauelemente nur nach vorgehender Entladung berühren 0V X1 X3 S11 S12 S21 S22 13 14 21 22 PA PA A1 A2 nQS QS UEXi UB Ui K1 K2 SRB 200EXi 1R 0V X1 X2 S11 S12 S21S22 13 14 23 24 PA PA A1 A2 Öffne...

Page 10: ... monitoring 11 Mounting The housing will be attached into the DIN rail with the rear side up slightly tilted forward and pushed above until locked Dismantling Push the rear side of the relay up tilt forward and demount 100 DIN rail acc EN 60715 2001 EXi circuits light blue non EXi circuits grey 22 5 122 121 without BMK ...

Page 11: ...tsschaltsysteme Facsimile 49 0 202 6474 100 Möddinghofe 30 D 42279 Wuppertal E Mail info schmersal com P O Box 240263 D 42232 Wuppertal Internet www schmersal com Production site Elan Schaltelemente GmbH Co KG Phone 49 0 641 9848 0 Im Ostpark 2 D 35435 Wettenberg Facsimile 49 0 641 9848 420 P O Box 1109 D 35429 Wettenberg E Mail info elan schmersal com Internet www elan de 1203578 470 08 02 06 08 ...

Reviews: