Installation manual
Page 10 of204
2.3 General safety regulations
Safety note:
In order to avoid damage to persons and property only qualified personnel is entitled to
work on the device. The term qualified personnel refers to persons who have
successfully completed electrotechnical training and are fully familiar with the
applicable rules and standards of electrical engineering.
The qualified person must become familiar with the operating instructions (see IEC364,
DIN VDE0100).
The qualified must have profound knowledge of the nartional accident prevention
regulations
The use of the device must be strictly limited to the intended use as specified in the
following list. The values of data listed under section "3.2 Characteristic device data"
must also be observed.
The contents of this installation manual is restricted to the basic function of the device
or its installation. The "Programming instructions PSCBR-C-10/11/12" contains a more
detailed description of the programming and re-parameterization of the devices. Exact
knowledge and understanding of these instructions is mandatory for a new installation
or modification of device functions or device parameters.
Commissioning (i.e. starting up the intended operation) is only permitted in strict
compliance with the EMC-directive. The EMC-testing regulations EN55011:2007 +
A2:2007 and EN 61000-6-2:2005 are used as basis.
Compliance with the conditions acc. to EN 60068-2-6 related to the values specified
under "Technical characteristics" is mandatory for storage and transport.
The wiring and connecting instructions in chapter "Installation" must be strictly
followed.
The applicable VDE-regulations and other special safety regulations of relevance for
the application must be strictly followed.
Evidence of the configured monitoring functions as well as their parameters and links
must be issued by means of a validation report.
The implementation of the module must be coordinated with the demands of the
responsible acceptance testing authority (e.g. TÜV or ELIA).
Do not install or operate damaged products. Report damages immediately to the
responsible forwarding agent.
Never open the housing and/or make unauthorized conversions.
Inputs and outputs for standard functions or digital and analog data transmitted via
communication modules must not be used for safety relevant applications.
Summary of Contents for PSCBR-C-10 Series
Page 1: ...Installation manual Page 1 of204 Installation Manual For PSCBR modules Series PSCBR C 10...
Page 178: ...Installation manual Page 178 of 204...
Page 181: ...Installation manual Page 181 of 204 Example for a risk analysis Gefahrenanalyse Risk analysis...