Parameterization of SSI-format:
Anzahl Clk
= Framelength
K Daten
O Status
Status information
Error Maske
0 = dont´t care
1 = aktiv
Ergebnis Maske
für Error = 0
(Auswertung aktiv)
Status
1
1
Mask
2
Mask
3
....
Mask
0
Start
Clk 0
Index
Daten
Index
Status
Mask
1
Clk 1
Clk 2
N-4
N-3
N-2
N-1
N-0
Clk
ClkN
Status
2
Status
0
Status
3
....
Result
2
Result
3
....
Result
0
Result
1
K Data
O Status
Index
Data
Index
Status
Number Clk
Status information
Fault mask
0 = on’t a
1 = active
Result mask
for error = 0
(evaluation active)