Installation manual
Page 102 of204
Example:
SSI-Frame length:
28 cycles
Data length:
22 bit
Status:
5 bit, 3 bit Fault + 2 bit Warning/ready for operation
K Daten
O Status
Status information
Error Maske
0 = dont´t care
1 = aktiv
Ergebnis Maske
für Error = False
(Auswertung aktiv)
Temperatur
1 = Error
Intezität
1 = Error
HW
1 = Error
Warnung
Verschmutzung
1 = Error
Betriebsart
1 = OK
1
1
0
0
1
0
0
0
0
Start
Clk 0
Clk ClkN
6 Clk
1Clk
Anzahl Clk
= Framelength
0
0
1
Clk 1
Clk 2
Clk 24
Clk 25
Clk 26
Clk 27
Clk 28
K Data
O Status
Temperature
Number Clk
Status information
Fault mask
0 = on’t a
1 = active
Result mask
for error = 0
(evaluation active)
Intensity
Warning:
Contamination
Operating