Installation manual
Page 11 of204
WARNING:
Using our devices contrary to the rules and conditions specified hereunder can lead to
injuries or fatalities as well as damage to connected devices and machines!
This will also cause the loss of all warranty and compensation claims against
Schmersal.
2.4 Operation and service
The module must always be de-energized before installation and removal, or before
disconnecting signal lines. For this purpose all live supply lines to the device must be checked
for safe isolation from supply
When installing or removing the module appropriate measures must be applied to prevent
electrostatic discharge to the externally arranged terminal and plug connections. Contact with
such terminals should be reduced to a minimum and earthing should by means of e.g. an
earthing strap should take place before and during these procedures.
2.5 Transport/storage
Information concerning transport, storage and proper handling must be strictly followed.
The climate related specifications in chapter "Technical data" must be complied with.
3 Device types
The series PSCBR-C-10/11/12 consists of
-
the basic devices PSCBR-C-10/11/11-2/12/12A/12-2
-
the extension modules PSCBR-E-31-12DI-10DIO
-
the communication modules PSCBR-F/52/53
Basic devices
Series PSCBR-C-10/11/12 is a compact fail-safe control system with optionally integrated
drive monitoring for one (PSCBR-C-10-SDM1/11-2) or two (PSCBR-C-10-SDM2/12-2) axes.
The device is freely programmable for reliable processing of both EMERGENCY STOP button,
two-hand control, light grid, operation mode switch, etc., but also of drive related safety
functions. Pre-configured modules for safety relevant signal pre-processing are available for a
vast number of input devices. The same applies for safety functions serving the purpose of
drive monitoring. Detailed information can be found in the programming manual.
The basic version of the device has 14 safe inputs and 3 cut-off channels, which can be
extended to max. 65 safe I/O's.
Single encoder solutions (incl. TTL/HTL, SIN(COS, Proxi-Sw.) as well as two encoder
solutions (e.g. Inc.-TTL or SSI and Inc..HTL) are supported for reliable speed and/or position
detection.
Extension modules
Summary of Contents for PSCBR-C-10 Series
Page 1: ...Installation manual Page 1 of204 Installation Manual For PSCBR modules Series PSCBR C 10...
Page 178: ...Installation manual Page 178 of 204...
Page 181: ...Installation manual Page 181 of 204 Example for a risk analysis Gefahrenanalyse Risk analysis...