Installation manual
Page 119 of204
Example 2: The release function of the outputs (ID 88) is additionaly AND combined with a FF
(Flip-Flop) . This FF-element prevents activation of the outputs after a reset with still
applied failures on the inputs. Just after a first correct detection of the input signals –
both input lines on “HIGH” within 3 sec. – the outputs are released.
Summary of Contents for PSCBR-C-10 Series
Page 1: ...Installation manual Page 1 of204 Installation Manual For PSCBR modules Series PSCBR C 10...
Page 178: ...Installation manual Page 178 of 204...
Page 181: ...Installation manual Page 181 of 204 Example for a risk analysis Gefahrenanalyse Risk analysis...