Installation manual
Page 127 of204
A 2121 / A 2122
Alarm message
Timeout receive message PSCBR-E-31-12DI-10DIO (address 2)
Cause
Message from expansion module not received in time
Remedy
Check connection to expansion module
A 2125 / A 2126
Alarm message
CRC fault transmission message PSCBR-E-31-12DI-10DIO (address
2)
Cause
Transmission message faulty
Remedy
Check configuration of PSCBR-E-31-12DI-10DIO serial number
A 2131
Alarm message
Timeout communication with expansion module PSCBR-E-31-12DI-
10DIO (address 2)
Cause
Installation of expansion module faulty
Remedy
Check connection to expansion module
A 2133
Alarm message
Expansion module PSCBR-E-31-12DI-10DIO (address 2) present,
but not configured
Cause
Faulty configuration
Remedy
Check configuration
A 3031 / A 3032
Alarm message
Pulse1 plausibility fault on expansion inlet EAEx.1
Cause
Configured Pulse1 voltage not applied to this input.
Remedy
Check the configuration of the digital input acc. to planning and
circuit diagram
Check wiring
A 3033 / A 3034
Alarm message
Pulse2 plausibility fault on expansion inlet EAEx.1
Cause
Configured Pulse2 voltage not applied to this input.
Remedy
Check the configuration of the digital input acc. to planning and
circuit diagram
Check wiring
A 3035 / A 3036
Alarm message
Faulty 24V signal on EAEx.1
Cause
No permanent 24V voltage applied to this input
Remedy
Check the voltage on the digital input!
Check wiring
Check whether Pulse1 or Pulse2 is applied
A 3037 / A 3038
Alarm message
Pulse1 plausibility fault on expansion inlet EAEx.2
Cause
Configured Pulse1 voltage not applied to this input.