Installation manual
Page 131 of204
A 3079 / A 3080
Alarm message
Pulse1 plausibility fault on expansion inlet EAEx.9
Cause
Configured Pulse2 voltage not applied to this input.
Remedy
Check the configuration of the digital input acc. to planning and
circuit diagram
Check wiring
A 3081 / A 3082
Alarm message
Pulse2 plausibility fault on expansion inlet EAEx.9
Cause
Configured Pulse2 voltage not applied to this input.
Remedy
Check the configuration of the digital input acc. to planning and
circuit diagram
Check wiring
A 3083 / A 3084
Alarm message
Faulty 24V signal on EAEx.9
Cause
No permanent 24V voltage applied to this input
Remedy
Check the voltage on the digital input!
Check wiring
Check whether Pulse1 or Pulse2 is applied
A 3085 / A 3086
Alarm message
Pulse1 plausibility fault on expansion inlet EAEx.10
Cause
Configured Pulse2 voltage not applied to this input.
Remedy
Check the configuration of the digital input acc. to planning and
circuit diagram
Check wiring
A 3087 / A 3088
Alarm message
Pulse2 plausibility fault on expansion inlet EAEx.10
Cause
Configured Pulse2 voltage not applied to this input.
Remedy
Check the configuration of the digital input acc. to planning and
circuit diagram
Check wiring
A 3089 / A 3090
Alarm message
Faulty 24V signal on EAEx.10
Cause
No permanent 24V voltage applied to this input
Remedy
Check the voltage on the digital input!
Check wiring
Check whether Pulse1 or Pulse2 is applied
A 3101 / A 3102
Alarm message
Pulse1 plausibility fault on input DI1
Cause
Configured Pulse1 voltage not applied to this input.
Remedy
Check the configuration of the digital input acc. to planning and
circuit diagram
Check wiring
Summary of Contents for PSCBR-C-10 Series