Installation manual
Page 138 of204
A 3197 / A 3198
Alarm message
Faulty OSSD input test
Cause
OSSD test faulty
Remedy
24V check the input voltage on all OSSD inputs
A 3209 / A 3210
Fault message
Encoder supply voltage X31 faulty.
Cause
Encoder supply voltage does not comply with configured
threshold
Component fault in module
Remedy
Check configuration!
Check encoder supply voltage
Switch device off/on.
A 3213 / A 3214
Fault message
Encoder supply voltage X32 faulty.
Cause
Encoder supply voltage does not comply with configured
threshold
Component fault in module
Remedy
Check configuration!
Check encoder supply voltage
Switch device off/on.
A 3225 / A 3226
Fault message
Deviation Ain1 to AIn2 too big
Cause
Different voltages on both inputs
configured threshold too low
Remedy
Check voltages on Ain1!
Check configuration of threshold/input filter
Switch device off/on.
A 3227 / A 3228
Fault message
Deviation Ain3 to AIn4 too big
Cause
Different voltages on both inputs
configured threshold too low
Remedy
Check voltages on Ain1!
Check configuration of threshold/input filter
Switch device off/on.
A 3229 / A 3230
Fault message
Plausibility test for encoder voltage faulty
Cause
Encoder voltage value
Remedy
Check encoder voltage supply
Check wiring of encoder voltage supply