Installation manual
Page 139 of204
A 3231 / A 3232
Fault message
Plausibility test for analog inputs faulty
Cause
Fault in analog input signal
Remedy
Check connection of analog inputs
Analog input voltage out of range
A 3233 / A 3234
Fault message
Open-circuit monitoring AIN1 has triggered
Cause
Open-circuit monitoring activated (< 1000 mV)
Remedy
Check configuration of activation/sensor
Check sensor connection
A 3235 / A 3236
Fault message
Open-circuit monitoring AIN2 has triggered
Cause
Open-circuit monitoring activated (< 1000 mV)
Remedy
Check configuration of activation/sensor
Check sensor connection
A 3301 / A 3302
Alarm message
Plausibility fault speed sensing axis 1
Cause
The difference between the two speed sensors is higher than the
configured speed shut-down threshold
Remedy
Check the theory of the distance once again using the data set in the
encoder configuration
Check the speed sensor
Use the SCOPE function to adjust superimposable speed signals
A 3303 / A 3304
Alarm message
Plausibility fault position sensing axis 1
Cause
The difference between the two position sensors is higher than the
configured incremental shut-down threshold
Remedy
Check the theory of the distance using the configured data or the
sensor setting
Check the position signal
Are all signals correctly connected to the 9-pole encoder plug?
Check the encoder plug for correct wiring.
If proximity switches are used, these are correctly connected.
Use the SCOPE function to adjust superimposable position signals
A 3307 / A 3308
Alarm message
Plausibility fault position range axis 1
Cause
The current position is outside the configured measuring length