Installation manual
Page 142 of204
A 3409 / A 3410
Alarm message
Difference level RS485Treiber2 fault INC_A or SSI_DATA faulty
Cause
No encoder connection
Wrong encoder type connected
Remedy
Check encoder connection
Check encoder wiring
A 3411 / A 3412
Fault message
Fault Sine/Cosine plausibility X31
Cause
Plausibility monitoring of individual tracks faulty
Remedy
Check encoder wiring
Sine- to Cosine- track must be linear
A 3413 / A 3414
Fault message
Fault Sine/Cosine plausibility X32
Cause
Plausibility monitoring of individual tracks faulty
Remedy
Check encoder wiring
Sine- to Cosine- track must be linear
A 3451 / A 3452
Alarm message
Faulty resolver frequency
Cause
Resolver frequency outside the permissible range. Exciter
frequency fault in resolver.
Remedy
Check the resolver frequency if it is within the permissible
range.
A 3453 / A3454
Fault message
Mean value of the resolver reference signal is outside the permissible
range.
Cause
Mean value of the resolver reference signal is outside the
permissible range.
Remedy
Check the connected resolver.
A 3457 / A3458
Fault message
Reference voltasge of the extension board is faulty
Cause
HW fault in the extension board
Remedy
Check the extension board
A 3459 / A3460
Fault message
The amplitude/pointer length formed from the two signals sine and
cosine (see also unit circle) is outside the permissible range.
Cause
Incorrect encoder configuration
Incorrect resolver connection
Remedy
Check the encoder configuration
Check the resolver connections