Installation manual
Page 143 of204
A 3461 / A3462
Fault message
The PIC reports a general status fault, e.g. when setting up a
connection or because a timeout occurred during processing.
Cause
Internal fault
Remedy
Power cycle of the device
Check the extension board
A 3463 / A3464
Fault message
Plausibility test between the analog sine signal abd the TTL-level at
the Schmitt-trigger output do not match.
Cause
Faulty encoder signals from the encoder
Remedy
Check the encoder connection
Check the encoder signal
A 3465 / A3466
Fault message
The quotient of arithmetic mean value / square mean value is outside
the permissible range.
Cause
Faulty encoder signals from encoder
Remedy
Check the encoder connection
Check the encoder signal
A 3467 / A3468
Fault message
Connection setup between CPU and PIC failed.
Cause
Faulty HW of the extension board
Remedy
Check the extension board
A 3469 / A3470
Fault message
Resolver_Quadrant
Cause
Faulty encoder signals from the encoder
Remedy
Check the encoder connection
Check the encoder signal
A 3471 / A3472
Fault message
Resolver_UENC
Cause
No voltage applied to the extension board
Remedy
Check whether voltage is correctly applied to the terminals of the
extension board.
A 3473 / A3474
Fault message
TTL/HTL signal faulty
Cause
Faulty encoder signals from the encoder
Remedy
Check the encoder connection
Check the encoder signal
A 3475 / A3476
Fault message
Resolver_TRACE Fault