Installation manual
Page 146 of204
A 3573 / A3574
Fault message
SSI STATUS 1. axis SSI Encoder
Cause
Evaluation of the 2nd status bit is faulty
Remedy
Check the encoder connection
Check the encoder signal
Replace the SSI-encoder
A 3575 / A3576
Fault message
SSI STATUS 1. axis SSI Encoder
Cause
Evaluation of the 3rd status bit is faulty
Remedy
Check the encoder connection
Check the encoder signal
Replace the SSI-encoder
A 3577 / A3578
Fault message
SSI STATUS 1. axis SSI Encoder
Cause
Evaluation of the 4th status bit is faulty
Remedy
Check the encoder connection
Check the encoder signal
Replace the SSI-encoder
A 3579 / A3580
Fault message
SSI STATUS 1. axis SSI Encoder
Cause
Evaluation of the 5th status bit is faulty
Remedy
Check the encoder connection
Check the encoder signal
Replace the SSI-encoder
A 3801 / A3802
Fault message
Faulty switching of output EAAx.1
Cause
Short-circuit of outPort with "24V" or "0V"
Remedy
Switch device off/on
A 3803 / A3804
Fault message
Faulty switching of output EAAx.2
Cause
Short-circuit of outPort with "24V" or "0V"
Remedy
Switch device off/on
A 3805 / A3806
Fault message
Faulty switching of output EAAx.3
Cause
Short-circuit of outPort with "24V" or "0V"
Remedy
Switch device off/on
A 3807 / A3808
Fault message
Faulty switching of output EAAx.4
Summary of Contents for PSCBR-C-10 Series