Installation manual
Page 148 of204
Remedy
In programming make sure that only one "Enable" is activated at a
time
A 4601 / A 4602
Alarm message
Monitoring range left and right of SLP1 activated at the same time
Cause
Multiple activation
Remedy
In programming make sure that only one "Enable" is activated at a
time
A 4603 / A 4604
Alarm message
Monitoring range left and right of SLP2 activated at the same time
Cause
Multiple activation
Remedy
In programming make sure that only one "Enable" is activated at a
time
A 4605 / A 4606
Alarm message
SLP1 Teach In status fault
Cause
SET and QUIT input have a faulty switching sequence
Remedy
Check input configuration
Check switching sequence
A 4607 / A 4608
Alarm message
SLP 2 Teach In status fault
Cause
SET and QUIT input have a faulty switching sequence
Remedy
Check configuration
Check switching sequence
A 4609 / A 4610
Alarm message
SLP1 Teach In position fault
Cause
Teach In position outside measuring range
Remedy
Check transfer position
A 4611 / A 4612
Alarm message
SLP2 Teach In position fault
Cause
Teach In position outside measuring range
Remedy
Check transfer position
A 4613 / A 4614
Alarm message
SLP1 Teach In SOS activation fault
Cause
The drive moved during Teach In (SOS fault)
Remedy
The drive must be stopped when using the Teach In function
Check whether SOS has already triggered
A 4615 / A 4616
Alarm message
SLP 2 Teach In SOS activation fault
Cause
The drive moved during Teach In (SOS fault)
Remedy
The drive must be stopped when using the Teach In function
Check whether SOS has already triggered
Summary of Contents for PSCBR-C-10 Series
Page 1: ...Installation manual Page 1 of204 Installation Manual For PSCBR modules Series PSCBR C 10...
Page 178: ...Installation manual Page 178 of 204...
Page 181: ...Installation manual Page 181 of 204 Example for a risk analysis Gefahrenanalyse Risk analysis...