Installation manual
Page 149 of204
A 4901 / A 4902
Alarm message
CCW and CW rotation monitoring SLI1 activated at the same time
Cause
Multiple activation
Remedy
In programming make sure that only one "Enable" is activated at a
time
A 4903 / A 4904
Alarm message
CCW and CW rotation monitoring SLI2 activated at the same time
Cause
Multiple activation
Remedy
In programming make sure that only one "Enable" is activated at a
time
A 5001 / A 5002
Alarm message
Test deactivation of digital inputs 1...14 faulty
Cause
Inputs are still active after deactivation
Remedy
Check wiring of digital inputs
A 6701 / A 6702
Alarm message
Timeout fault MET
Cause
Input element with time monitoring is faulty
Remedy
Check wiring of input element
Input element faulty
A 6703 / A 6704
Alarm message
Timeout fault MEZ
Cause
Two-hand control element with time monitoring is faulty
Remedy
Check wiring of input element
Input element faulty
11.3
Fatal Fault list PSCBR
F 1001
Fault message
Configuration data were incorrectly loaded into the monitoring
device
Cause
Disturbed connection when loading the program into the
monitoring device.
Remedy
Reload the configuration data, then switch module off/on.
F 1003
Fault message
Configuration data invalid for software version of module!
Cause
Module configured with incorrect software version of the
programming desktop.
Remedy
Parameterize the module with the approved version of the
programming desktop, the switch the module off/on.