Installation manual
Page 154 of204
Remedy
Check device supply voltage!
Switch device off/on.
F 3204
Fault message
Internal supply voltage 5.7V faulty
Cause
Supply voltage for module not correct!
Component fault in module
Remedy
Check device supply voltage!
Switch device off/on.
F 3217 / F 3218
Fault message
Internal supply voltage 5V faulty
Cause
Supply voltage for module not correct!
Component fault in module
Remedy
Check device supply voltage!
Switch device off/on.
F 3306
Alarm message
Plausibility fault position switching axis 1
Cause
During position switching SOS, SLI or SDI is permanently
activated.
Remedy
Check activation of SOS
Check activation of SLI
Activation of SDI (only for monitoring via position)
F 3316
Fault message
Fault in encoder alignment axis 1
Cause
Incorrect position triggering by system A
Remedy
Check encoder configuration
Switch device off/on.
F 3326
Fault message
Plausibility fault position switching axis 2
Cause
During position switching SOS, SLI or SDI is permanently
activated.
Remedy
Check activation of SOS
Check activation of SLI
Activation of SDI (only for monitoring via position)
F 3336
Fault message
Fault in encoder alignment axis 2
Cause
Incorrect position triggering by system A
Remedy
Check encoder configuration
Switch device off/on.
F 3603 / F 3604
Fault message
Faulty switching of relay K1
Cause
Internal triggering of relay faulty
Summary of Contents for PSCBR-C-10 Series
Page 1: ...Installation manual Page 1 of204 Installation Manual For PSCBR modules Series PSCBR C 10...
Page 178: ...Installation manual Page 178 of 204...