Installation manual
Page 163 of204
No.
Type
Encoder to
interface
X31/32
Type
Encoder to
interface
X31/34
Type
Encoder to
X 23
Safe
speed
Safe
direction
Safe
position
Fault exclusion
DC
1-channel
partial
system
2-channel
partial
system
dynamic
2-channel
partial
system
non-
dynamic
(standstill
monitoring)
58
Incremental
Resolver
NC
X
X
n.a.
99%
99%
65
Incremental
SSI
NC
X
X
X
n.a.
99%
90-95%
2
SIN/COS
NC
NC
X
X
Fault exclusion mech. shaft breakage, positive
encoder shaft connection required
90%
99%
90-95%
52
SIN/COS
Incremental
NC
X
X
n.a.
99%
95-99%
4
SIN/COS
NC
1 x Bero
X
X
n.a.
99%
90-95%
50
SIN/COS
NC
2 x Bero 90°
X
X
n.a.
99%
95-99%
55
SIN/COS
HTL
NC
X
X
n.a.
99%
95-99%
59
SIN/COS
Resolver
NC
X
X
n.a.
99%
99%
Summary of Contents for PSCBR-C-10 Series
Page 1: ...Installation manual Page 1 of204 Installation Manual For PSCBR modules Series PSCBR C 10...
Page 178: ...Installation manual Page 178 of 204...
Page 181: ...Installation manual Page 181 of 204 Example for a risk analysis Gefahrenanalyse Risk analysis...