Installation manual
Page 164 of204
No.
Type
Encoder to
interface
X31/32
Type
Encoder to
interface
X31/34
Type
Encoder to
X 23
Safe
speed
Safe
direction
Safe
position
Fault exclusion
DC
1-channel
partial
system
2-channel
partial
system
dynamic
2-channel
partial
system
non-
dynamic
(standstill
monitoring)
66
SIN/COS
SSI
NC
X
X
X
n.a.
99%
95-99%
8
SSI
NC
2 x Bero 90°
X
X
X
n.a.
99%
90-95%
63
SSI
SIN/COS
NC
X
X
X
n.a.
99%
95-99%
60
SSI
Resolver
NC
X
X
X
n.a.
99%
95-99%
67
SSI
SSI
NC
X
X
X
n.a.
99%
90-95%
61
NC
SIN/COS
NC
X
X
Fault exclusion mech. shaft breakage, positive
encoder shaft connection required
90%
99%
90-95%
57
NC
Resolver
NC
X
X
Fault exclusion mech. shaft breakage, positive
encoder shaft connection required
90%
99%
90-95%