Example of software specification
Con
s.-
No.
Safety function
Plr
Measuring
value /sensor
Solution new
Input/activation
Response/output
1.4
Monitoring V_Rope to
V_Nominal
Monitoring of differences
between speed of main
drive and rope drive for
maximum value
d
Digital
incremental
encoder,
tachometer
generator rope
sheave
Monitoring by means of tested
function SLS + SAC with comparison
of speed ranges /analog value
ranges = comparison for diagnose of
the speed detection
Shut-down dual-channel new (see
below)
Permanently
Reset:
Acknowledgement
button
Operation stop
SF 1.3.1
1.6
Backstop
Monitoring for reversing
d
Mechanical limit
switch 22S2
Digital
incremental
encoder
Monitoring by means of tested
function direction monitoring SDI
EMERGENCY
(auxiliary contact
28K4
– reversing)
Reset:
Acknowledgement
button
Operation stop
SF 1.3.1
1.15 Step-by-step shut-down 3
Activation of the safety
brake
e
-
Processing of SF in Safe PLC
SF 1.2
SF 1.3.2
SF 1.7
SF 1.8
Setting the safety
brake
1.8
Standstill functional
d
Digital
incremental
encoder
Standstill monitoring by means of
tested function SOS
Regulator lock
OR
Set service brake
SF 1.15/
Set safety brake
1.9
direction monitoring
e
Digital
incremental
encoder,
Monitoring by means of tested
function direction monitoring SDI
28K1 = FORW.
28K2 = BACK
= safe <signals from
control "Frey"""
Operation stop
SF 1.3.1