Installation manual
Page 187 of 204
14.3.4.2
Example for hardware specification
Safety function
Safely reduced speed
SF 2.2
Safely monitored limited speed with door open
Type
Designation Function
Design
.
Characteristic data
Note
Archite
cture
MTTFD
[Years]
PFH
[1/h]
B10d
Source
DC
[%]
Source
Sensor
Sensor 1
Door lock
– Monitoring of the
access door
A 3.1
4
10000
0
Data
sheet
99
Inst.
manual
op.
PSCBR
Sensor 2.1
Incremental encoder
– Motor
feedback
SIN/COS
G 1.1
4
30
Gen.
specifica
tion
99
Inst.
manual
op.
PSCBR
Cat. 4 in
connectio
n with
selection
PSCBR
PES
Safety PLC
Central safety PLC for control and
evaluation of safety relevant
functions
A 4.1
1,4
E-8
Data
sheet
PSCBR
Actuator
STO
Safe Torque Off on inverter
A 5.1
4
150
Data
sheet
inverter
99
Inst.
manual
op.
PSCBR
Cat. 4 in
connectio
n with
dual-
channel
Mains
contactor
Contactor in mains line of inverter
K 5.1
4
20 E6
Data
sheet
contacto
r
99
Inst.
manual
op.
PSCBR
Cat. 4 in
connectio
n with
dual-
channel