Calculation acc. to EN 13849-1:
Channel A
– shut-down via mains contactor:
Component
MTTFD [years]
DC
Door closer
B10d = 100000
Nop = 30/AT = 10000/year(309 AT/year)
DCSwitch = 99%
SIN/COS
encoder:
MTTFD_SinCos = 30 years
DCEncoder = 99%
PES
PFH = 1.4 * 10-8
DCPES = 99%
Mains
contactor
B10d = 20 * 106
Nop = 20/AT = 3990/year(309 AT/year)
DCPES = 60%