Installation manual
Page 197 of 204
Example encoder configuration:
Validation report
Axis configuration / sensor interface
Axis 1
General parameters
Measuring distance:
500
0
Type:
Rotational
No
Position processing:
Active
Maximum speed:
2000
0
Incremental shut-down:
10000
0
Shut-down speed:
100
0
Sensors
0
0
Type:
SSI-standard
SSI-standard
Format:
Binary
Binary
Direction of rotation:
Ascending
Ascending
Supply voltage:
0
0
Resolution:
1024
Steps/1000mm 64
Steps/1000mm
Offset:
0
Steps
0
Steps
General parameters correctly configured
Parameter sensor 1 correct
Parameter sensor 2 correct