Installation manual
Page 201 of 204
Two-hand button
Switch type
Comment
Classification
category
Classification SIL
2 two-way switch
Two-hand button higher
requirements
Type III C Pl e
SIL3
2 normally open
Two-hand button
monitored
Type III A Pl e
SIL1
Note: With these inPort elements a fixed pulse assignment takes place, which cannot be
influenced by the user!
Light curtain
Switch type
Comment
Classification
category
Classification SIL
2 normally closed
Light curtain higher
requirements
Pl e
SIL 3
2 normally closed time
monitored
Light curtain monitored
Pl e
SIL 3
1 normally open + 1
normally closed
Light curtain higher
requirements
Pl e
SIL 3
1 normally open + 1
normally closed time
monitored
Light curtain monitored
Pl e
SIL 3
Mode selector switch
Switch type
Comment
Classification
category
Classification SIL
2 positions
Mode selector switch
monitored
Pl e
SIL 3
3 positions
Mode selector switch
monitored
Pl e
SIL 3
Safety note
: When changing the status of the switch the SafePLC program to be created
must ensure that the outPorts of the module are deactivated (note: Standard 60204-Part1-
Paragraph 9.2.3).
Sensor
Switch type
Comment
Classification
category
Classification SIL
1 normally closed
Sensor input standard
Pl d
SIL 2
1 normally open
Sensor input standard
Pl d
SIL 2
2 normally closed
Sensor input higher
requirements
Pl e
SIL 3
2 normally closed time
monitored
Sensor input monitored
Pl e
SIL 3
1 normally open + 1
normally closed
Sensor input higher
requirements
Pl e
SIL 3
1 normally open + 1
normally closed time
monitored
Sensor input monitored
Pl e
SIL 3