Safety note:
Pl d or higher in accordance with EN ISO 13849-1 is achieved by using switching
elements / sensors with positively opening contacts or positive actuation acc. to
EN 60947-5-1
Using devices for which the fault exclusion double fault for the intended safety level
can be specified for the switching elements, is permitted. We would like to draw your
attention to the applicable regulations in the EC machine directive 2006/42/EC.