Installation manual
Page 43 of204
Type
Encoder to
interface
X31/32
Type
Encoder to
interface
X31/34
Type
Encoder to
X 23
Safe
speed
Safe
direction
Safe
position
Fault exclusion
DC
1-channel
partial
system
2-channel
partial
system
dynamic
2-channel
partial
system
non-
dynamic
(standstill
monitoring)
Incremental
Resolver
NC
X
X
n.a.
99%
99%
Incremental
SSI
NC
X
X
X
n.a.
99%
90-95%
SIN/COS
NC
NC
X
X
Fault exclusion mech. shaft breakage, positive
encoder shaft connection required
90%
99%
90-95%
SIN/COS
Incremental
NC
X
X
n.a.
99%
95-99%
SIN/COS
NC
1 x Bero
X
X
n.a.
99%
90-95%
SIN/COS
NC
2 x Bero 90°
X
X
n.a.
99%
95-99%
SIN/COS
HTL
NC
X
X
n.a.
99%
95-99%
SIN/COS
Resolver
NC
X
X
n.a.
99%
99%