4.3.3.1.3 Single-pole switching relay or semi-conductor output with dual-channel external circuit
with testing
For safety applications from PI c and higher acc. to EN ISO 13849-1 we strongly recommend or
even demand the control of two external cutout elements. Furthermore, the setup for testing the
complete chain and a message/warning device for an detected fault is required for achieving PI
c or higher - see also remarks under 4.3.3.1.2.
DO0_P
X43
X42
DO0_M
DO1_P
DO1_M
NC
NC
DO.1
DO.2
X65
DI13
DI14
P1
P2
L +
L -
Fig.:
Single-channel switching outout DO0_P with dual-channel external circuit and monitoring
at output 1 as group feedback
The two external monitoring contacts are switched in series, supplied by the clock signal P1 and
read via input 1. Input 1 was chosen as readback input, but any other input can be assigned for
this purpose.