Installation manual
Page 65 of204
4.3.3.1.7 Dual-channel output with semi-conductor output and external control circuit in PI e
For safety applications from PI d and higher acc. to EN ISO 13849-1. The external circuit is
controlled in dual-channel mode via the semi-conductor outputs. For PL e acc. to EN ISO 13849-1
PI e is demanded for the external circuit
STO
Pl e
DO0_P
X43
DO0_M
DO1_P
DO1_M
4.3.3.1.8 Wiring of an auxiliary output
Both semi-conductor outputs implemented on the PSCBR1X module can be wired for functional
applications. These outputs are not pulse-commutated.
L+
L-
O.1
O.2
X13
Fig.: Wiring of an auxiliary output
Applications with auxiliary outputs are not accepted for safety related applications!