All contactors in the environment of the power converter must be equipped with
appropriate suppressor circuits.
Suitable measures to protect against overvoltages must be applied.
Additional safety regulations when using as PESSRAL acc. to EN81
Install the device at a distance of at least 200 mm from the HF-transmitting facility
(WLAN, GSM, etc.). The transmitting facilities must thereby not exceed the max. field
strengths as specified above.
The device must be installed in a closed housing, IP5X or better.