2.1 Intended use
Devices of the PSCBR-C-10/11/12 series are programmable fail-safe control system intended
for the establishment of emergency shut-down features and functions. The devices are
intended for use in
-
EMERGENCY STOP facilities,
-
as safety component as defined by the EC machine directive 2006/42/EC,
-
as PES for risk reduction as defined by EN 61508,
-
in safety circuits acc. to EN 60204 and EN 60204-32,
-
as PES for functional safety as defined by EN 62061,
-
as SRP/CS as defined by EN 13849,
-
as device for establishing the safety functions acc. to EN 61800-5-2,
-
as logic unit for converting and processing signals in two-hand control acc. to EN 574.
The devices PSCBR-C-10/P and PSCBR-C-10-SDM1/P are suitable for use as PESSRAL
(programmable electronic system in safety related applications for elevators) in elevator
technology, i.e in the validity range of EN81-1. Devices of the basic series without the
extension "/P" cannot be used in this field of application.
Warning:
Devices of the basic series without the extension "/P" cannot be used in this field of
application of EN81-1!
The devices of series PSCBR-C-10/11/12 incl. the extension module PSCBR-E-
31-12DI-10DIO are safety components as specified in appendix IV of the EC
machine directive 2006/42/EC.
They were developed, designed and manufactured in compliance with the above
mentioned directive as well as the EC-directive EC-EMC directive 2004/108/EC
See appendix "EC Declaration of Conformity"
2.2 Use in regions with UL/CSA requirements
Modules of the PSCBR-series can be used in the USA and Canada when observing the
following boundary conditions:
-
the switching voltage of the output relays must be limited to max. 24 V.
-
a power supply unit meeting the requirement CLASS 2 acc. to UL 1310 must be used
for supplying electric power to the PSCBR modules and their inputs and outputs
Under these prerequisites no UL/CSA approval is required and the PSCBR-series can be used
in switchgear in accordance with UL 508A.