Installation manual
Page 94 of204
5.11.3.2
Connection of an absolute encoder as slave
Sub-D-
Stecker
(9 polig)
SMX
Absolut-
Encoder
(Slave-Betrieb)
n.c.
Ground
n.c.
CLK-
DATA+
DATA-
n.c.
CLK+
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
externes Abtastsystem
Versorgungsspannung
24 V DC Supply GND
With this type of connection both clock signals and data are read in. In this example the module
does not supply the encoder with voltage.
Absolute
encoder
(Slave mode)
Sub-D plug
(9 pin)
PSCBR
Supply voltage
external sensing system