Installation manual
Page 103 of204
5.12.2.2
Incremental encoder:
Physical Layer:
RS-422 compatible
Measuring signal A/B.
Track with 90 degree phase difference
maximum frequency of input cycles
200 KHz
1)
or 500 kHz
2)
Diagnoses:
Diagnose
Parameters
Fault threshold
Supply voltage monitoring
Fixed values
5 V, 8V, 10V, 12V, 20V,
24V
+/- 20 % +/-2 %(measuring
tolerance)
Monitoring of differential level
on input
Fixed value RS 485-level
+/- 20 % +/-2 %(measuring
tolerance)
Monitoring of the counting
signal separated for each
track A/B
Fixed value
DP > 4 increments
5.12.2.3
SinusCosinus encoder
– standard mode
Physical Layer:
+/- 0.5 Vss (without voltage offset)
Measuring signal A/B.
Track with 90 degree phase difference
Maximum frequency of input clock pulses. 200 KHz
1)
or 500 kHz
2)
Diagnoses:
Diagnose
Parameters
Fault threshold
Supply voltage monitoring
Fixed values
5 V, 8V, 10V, 12V, 20V, 24V
+/- 20 % +/-2 %(measuring
tolerance)
Monitoring of amplitude
SIN²+COS²
Fixed value 1V
SS
65 % of 1 V
SS
+/-
2.5 %(measuring tolerance)
Monitoring of phases A/B
Fixed value 90°
+/- 30° +/-5° measuring
tolerance)
5.12.2.4
SinusCosinus encoder
– high resolution mode:
Physical Layer:
+/- 0.5 Vss (without voltage offset)
Measuring signal A/B.
Track with 90 degree phase difference
Maximum frequency of input clock pulses. 15 kHz
2)
Diagnoses:
Diagnose
Parameters
Fault threshold
Supply voltage monitoring
Fixed values
5 V, 8V, 10V, 12V, 20V, 24V
+/- 20 % +/-2 %(measuring
tolerance)
Monitoring of amplitude
SIN²+COS²
Fixed value 1V
SS
65 % of 1 V
SS
+/-
2.5 %(measuring tolerance)
Monitoring of phases A/B
Fixed value 90°
+/- 30° +/-5° measuring
tolerance)
Monitoring of counting signal
/ signal phase quadrant
Fixed value
+/- 45°
Summary of Contents for PSCBR-C-10 Series
Page 1: ...Installation manual Page 1 of204 Installation Manual For PSCBR modules Series PSCBR C 10...
Page 178: ...Installation manual Page 178 of 204...
Page 181: ...Installation manual Page 181 of 204 Example for a risk analysis Gefahrenanalyse Risk analysis...