Installation manual
Page 124 of204
10.1 Environmental conditions
Class of protection
IP 52
Ambient temperature
0 °C* ... 50 °C
Climatic category
3 acc. to DIN 50 178
Lifetime
90000h at 50 °C ambient
10.2 Safety related characteristic data
Max. obtainable safety class
SIL 3 acc. to EN61508
Category 4 acc. to EN945-1
Performance-Level e acc. to
EN ISO 13849-1
System structure
2-channel with diagnose (1002)
Rating of operating mode
"high demand" acc. to EN 61508 (high demand
rate)
Probability of an endangering failure
per hour (PFH-value)
PSCBR-C-10, PSCBR-C-10-SDM1, PSCBR-C-
10-SDM2 und PSCBR-C-10-SDM2A < 1,4 E-8
(14FIT)
Proof-Test-Interval (EN61508)
20 years, after this time the module must be
replaced