3.1.1.3 PSCBR-C-10-SDM2
Type designation
Device design
Design of module with the following
periphery:
2
sensor interfaces
14
digital inputs, alternatively 4 counting
inputs
2
pulse outputs
2
relay outputs
2
LOSIDE
2
HISIDE
2
signal outputs
1
diagnostic and configuration interface
1
function button
1
7-segment display
1
status LED
14
status LEDs for inputs
2
status LEDs for pulse outputs
2
status LEDs for relay outputs
2
status LEDs for HISIDE
1
backplane bus interface
Characteristics of the module:
Logic processing up to Pl e EN ISO 13849-1 or SIL 3 acc. to EN 61508.
Movement monitoring of one or two axes up to Pl e EN ISO 13849-1 or SIL 3 acc. to
EN 61508
Speed monitoring
RPM-monitoring
standstill monitoring
Sense of rotation monitoring
Safe incremental dimension
Emergency Stop monitoring
Position monitoring
Position range monitoring
Trend range monitoring
Target position monitoring
Freely programmable small control system for up to 800 IL instructions
Logic diagram oriented programming
Pulse outputs for cross-shorting detection of digital input signals
Counting inputs as alternatives to the digital inputs
Safety function of external contact monitoring for connected switchgear
Monitored relay outputs for safety relevant functions
Monitored HISIDE/LOWSIDE outputs for safety relevant functions
CAN-communication in connection with the PSCBR-F for diagnose via backplane bus
system
Assembly on top hat rail