Installation manual
Page 162 of204
12 Encoder types
No.
Type
Encoder to
interface
X31/32
Type
Encoder to
interface
X31/34
Type
Encoder to
X 23
Safe
speed
Safe
direction
Safe
position
Fault exclusion
DC
1-channel
partial
system
2-channel
partial
system
dynamic
2-channel
partial
system
non-
dynamic
(standstill
monitoring)
69
NC
NC
1 x Bero
+
1 x Bero
X
Fault exclusion mech. shaft breakage, positive
encoder shaft connection required, if common
elements are in use.
n.a.
99%
80-90%
1
Incremental
NC
NC
X
Fault exclusion mech. shaft breakage, positive
encoder shaft connection required
60%
99%
80-90%
51
Incremental
Incremental
NC
X
X
n.a.
99%
95%
3
Incremental
NC
1 x Bero
X
n.a.
99%
90-95%
68
Incremental
NC
2 x Bero 90°
X
X
n.a.
99%
90-95%
62
Incremental
SIN/COS
NC
X
X
n.a.
99%
99%
54
Incremental
HTL
NC
X
X
n.a.
99%
90-95%